WHY USE TRAPS?
They are necessary to remove interference components in carrier and sample gas streams in GCs and on-line instruments. For the GCs, a combination of moisture, hydrocarbon and oxygen traps is used to prevent column degradation a well known problem increasing detector noise and creates ghost peaks. The use of such traps is also necessary on make-up gas that must also be interference free.
A selection of single component removal traps or multi-components removal traps is also necessary to remove interference components present in sample lines with on-line instruments.
Our selection of traps is normally used when the LDP1000 (Gas purifier) cannot be used.
MOISTURE REMOVAL LDH20-T
Our Moisture Trap LDH2O-T is used to remove moisture at the source. It can be installed on any carrier gas line, make-up gas line and sample line to remove moisture interference. Different sizes and connection types are available depending on the flow rate and the purity specifications needed.
HYDROCARBON REMOVAL LDHC-T
The Hydrocarbons Trap series is commonly used when trace HC's are present in sample, carrier or make-up gas lines. Presence of hydrocarbons in gas lines creates a deterioration oin some detectors like a common PED. Different sizes and connection types are available depending on the flow rate and the purity specifications needed.
OXYGEN REMOVAL LDO2-T
The Oxygen Trap series is also offered with numerous configuration types that can cover any needs.
MULTI-COMPONENTS REMOVAL LDH2O/HC/O2-T
Our LDetek Multi Trap that combines removal of H2O/HCs and O2 in one unit is also a great alternative when the removal of all interference components is necessary. It avoids having complex tubing configuration with multiple fittings that increase leakage possibilities in the installation. Our Multi-Components Trap can be configured the way you need it.
LDMINIPURIFIER
The LDminipurifier for noble gas is the best solution for generating high purity Argon/Helium for any gas chromatograph when space available is restricted. It's compact design is ideal for portable gas analyzers. It can also be the solution for eliminating problems coming from any source of contamination that results in columns degradation and detector instability.